Sales are growing so quickly that some installers wonder whether heat pumps could even wipe out the demand for new air conditioners in a few years and put a significant dent in the number of natural gas furnaces.

  • nebula@lemmy.ca
    link
    fedilink
    arrow-up
    19
    arrow-down
    1
    ·
    1 year ago

    Baseboard heating is 100% efficient but heat pumps can be up to 400% efficient. Depending on model and outside temperature. This is because hear pump is not generating heat its just moving it from one place to another. In AC mode from inside to outside of house and in heating mode from outside to inside.

    • Rodeo@lemmy.ca
      link
      fedilink
      arrow-up
      1
      arrow-down
      10
      ·
      1 year ago

      I’m no engineer but I’m certain there is no such thing as 100% efficiency, let alone 400% lol

      • Space_Can@lemmy.blahaj.zone
        link
        fedilink
        arrow-up
        15
        ·
        edit-2
        1 year ago

        Mechanical engineer here!

        What the OP is referring to as “Efficiency” is what’s known in the industry as COP (coefficient of performance).

        A system’s COP is equal to the amount of useful heat energy supplied or removed by the system divided by the amount of energy used to do that work.

        If your heat pump uses 10 Joules of electrical energy to move 40 Joules of heat energy from the outside into your house, that heat pump is operating at a COP of 4 (or 400%).

        Only heat pumps can have a COP of >1, due to conservation of energy. A traditional gas or electric heater uses combustion or electrical resistance to lossily convert electrical or chemical energy into heat energy.

        • Rodeo@lemmy.ca
          link
          fedilink
          arrow-up
          2
          arrow-down
          7
          ·
          1 year ago

          So he’s not talking about efficiency.

          Please explain to the down voting morons why 100% efficiency is impossible.

          • Space_Can@lemmy.blahaj.zone
            link
            fedilink
            arrow-up
            8
            arrow-down
            1
            ·
            1 year ago

            If everyone in the world had an engineering degree the distinction might have been important, but complaining about it in this context is just pedantic.

            • Rodeo@lemmy.ca
              link
              fedilink
              arrow-up
              4
              arrow-down
              3
              ·
              1 year ago

              I really don’t agree with that. “Baseboard heaters are 100% efficient” is an objectively false statement. And efficiency is a very common and basic concept that doesn’t require a degree to understand.

              I think instead of just dismissing it as pedantic, people could learn something.

              • nebula@lemmy.ca
                link
                fedilink
                arrow-up
                1
                ·
                edit-2
                1 year ago

                Maybe try looking it up.

                Electric resistance heating is 100% energy efficient in the sense that all the incoming electric energy is converted to heat

                • John Stonier@mstdn.ca
                  link
                  fedilink
                  arrow-up
                  1
                  ·
                  1 year ago

                  @nebula @Rodeo

                  Here’s how to compare baseboards to heat pumps.

                  Baseboards create heat through resistive loads. As all the energy creates heat, you can say they are 100% efficient, but that is misleading if you take that to be good.

                  Heat pumps simply move heat, in either direction, to heat, or cool, and they do this using 1/3rd the energy.

                  Today’s heat pumps work at much lower air temperatures, can also use ground loops, or exchange heat from water bodies. #HeatPumps

      • ampedwolfman@lemmy.world
        link
        fedilink
        arrow-up
        2
        ·
        1 year ago

        It’s in relation to a standard ac unit. It’s capable of doing the same work with 1/4 the power or at the same power do 4x the work.